Additel ADT760-D Automatic Handheld Pressure Calibrator

Additel ADT760-D Automatic Handheld Pressure Calibrator

  • Fully automatic calibrator with built-in pump and controller
  • Switchable internal pressure modules for expandable ranges
  • Accuracy (1 year) of 0.02%FS
  • External pressure modules available (measure only)
  • Less than 4 lbs (1.8 kg) for handheld operation
  • Source pressure, measure pressure and electrical
  • 4 channels
  • Optional HART communications
  • Optional data logging and task documenting
  • USB and Wi-Fi communication
  • ISO 17025-accredited calibration w/data included

 

More information contact below :

GET QUOTE021-4585-06180811-1519-949

Description

The Additel 760 series Automatic Handheld Pressure Calibrator takes portable pressure calibration to new levels. Weighing less than 4 lbs (1.8 kg), the ADT760’s innovative design contains a built-in pump, precision pressure sensor, internal controller and a large touch-screen color display. To generate pressure, simply key in the desired pressure and the Additel 760 will do the rest. Each unit has four channels: one internal pressure channel for source and measure pressures, two external pressure measurement channels, and one electronic measure and source channel. This series of calibrator has three standard models with the option of adding HART communications, documentation and data logging.

ADT760-D
The 760-D gives you differential and gauge pressure but at a higher pressure range than the ADT760-LLP. Covering the range of -12.5 to 35 psi (-0.86 to 2.5 bar) and with an accuracy of 0.02%FS, the ADT760-D is an ideal solution to cover very common gauge and differential pressure measurements. The Additel 760-D comes with an internal module covering its full range, but lower pressure configurations down to ±10 inH2O differential can be purchased to improve accuracy at lower pressures.

Documenting Process Functionality
Each model of the Additel 760 series has an option incorporating documentation and communication functions turning your 760 into a multifunction documenting process calibrator. This feature provides HART communication, task documentation and data logging.

  • Gauge calibration for differential and gauge type pressures
  • Low pressure calibration
  • Transmitter calibration for absolute and gauge type pressures
  • Switch calibration for absolute and gauge type pressures
  • HART-smart transmitter calibration ( -DL version only )
  • Pressure monitoring and data logging (-DL version only
Pressure Specification
Max Pressure Range-12.5 to 35 psi (-0.86 to 2.5 bar)
Accuracy0.02% FS
Stability<0.005% FS
Pressure TypeDifferential, Gauge
Over Range Indication1.2
Resolution6 digits
Measurement UnitsPa, hPa, kPa, mPa, bar, mbar, msi, mmHg @ 0°C, cmHg @ 0°C, mHg @ 0°C, inHg @ 0°C, inH2O @ 4°C, mmH2O @ 4°C, cmH2O @ 4°C, mH2O @ 4°C, inH2O @ 20°C, mmH2O @ 20°C, cmH2O @ 20°C, mH2O @ 20°C, inH2O @ 68°C, kg/m2, mtorr, torr, lb/ft2, tsi, custom
ConnectionHose, 5 ft (1.5 m), with built-in filter to 1/4BSPF, 1/4NPTF, and M20F adapters
Pressure Output Rate<10 Seconds (35 psi/5 ml)
Selection Guide – Differential Pressure
ModuleModule Range[6]MediaAccuracy (%FS)[1]Burst Pressure760-LLP760-D760-MA
inH2Ombar
DP025±0.25±0.62G0.2[2]100x
DP050±0.5±1.25G0.1[3]100x
DP1±1±2.5G0.05[4]100x
DP2±2±5G0.05[4]100x
DP5±5±10G0.05[4]50x
DP10±10±25G0.05[4]20x
DP20±20±50G0.0520x
DP30±30±75G0.0520x
DP50±50±125G0.053x
DP100±100±250G0.023x
DP150±150±350G0.023x
DP300±300±700G0.023x
DP400-380 to 400-950 to 1KG0.023x
DP800-380 to 800-950 to 2KG0.023x
DP1K-380 to 1K-950 to 2.5KG0.023x
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.
Selection Guide – Gauge Pressure
ModuleModule Range[6]MediaAccuracy (%FS)[1]Burst Pressure760-LLP760-D760-MA
psi
bar
CP10±10±0.7G0.02[5]3x
CP15-13.5 to 15-0.95 to 1G0.02[5]3x
CP30-13.5 to 30-0.95 to 2G0.02[5]3x
CP35-13.5 to 35-0.95 to 2.5G0.02[5]3x
CP50-13.5 to 50-0.95 to 3.5G0.02[5]3x
CP100-13.5 to 100-0.95 to 7G0.02[5]3x
CP150-13.5 to 150-0.95 to 10G0.02[5]3x
CP200-13.5 to 200-0.95 to 14G0.02[5]3x
CP300-13.5 to 300-0.95 to 20G0.02[5]3x
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.
ModuleModule RangeMediaAccuracy (%FS)[1]Burst Pressure
psibar
CP10±10±0.7G0.02[5]3x
CP15-13.5 to 15-0.95 to 1G0.02[5]3x
CP30-13.5 to 30-0.95 to 2G0.02[5]3x
CP35-13.5 to 35-0.95 to 2.5G0.02[5]3x
CP50-13.5 to 50-0.95 to 3.5G0.02[5]3x
Electrical Specification
RangeResolutionAccuracyNote
mA Measure±30 mA0.0001 mA0.01%RD+0.005%FSImpedance<10Ω
V Measure±30 V0.0001 V0.01%RD+0.005%FSImpedance >1MΩ
mA Source24 mA0.001 mA0.01%RD+0.005%FS20 mA @ 1K
Loop Power Source24 VN/A±1 V50 mA (Max Loading)
Pressure SwitchOpen, close. Support for mechanical switches and NPN/PNP digital switches.
Temperature Compensation41°F to 95°F (5°C to 35°C)
Temperature Coefficient< ± ( 0.001%RD + 0.001%FS ) / °C outside of 5°C to 35°C
General Specifications
SpecificationDescription
ChannelsFour total: one electrical, one internal pressure, two external pressure (measure only)
Enclosure IP RatingIP52 water and dust proof
BatteryRechargeable Li-Ion battery, typically 10 hours of operation, recharges in less than 4 hours
DisplayColor 800 x 480 TFT 5-inch touch screen
CommunicationsUSB, WiFi
Weight<4 lbs (<1.8 kg)
Size9.3 x 4.3 x 2.8 in (235 x 110 x 70 mm)
CertificationISO17025 accredited certificate with data included
HART CommunicationsOptional (ADT760-X-DL model)
Data LoggingOptional (ADT760-X-DL model), up to 1,000,000 readings (date and time stamped)
Task DocumentationOptional (ADT760-X-DL model) up to 1000 tasks
Automation FunctionsSwitch test, auto step, leak test
Misuse ProtectionUp to 30 V on any two sockets
Multi Lingual InterfaceEnglish, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian
Pump Life>500,000 cycles
PowerRechargeable Li-Ion battery, external power: 110/220 V power adapter 10 V
Environment SpecificationsOperation: 32°F to 122°F (0°C to 50°C), 0-90% RH, less than 3,000 meters Compensated temperature: 32°F to 122°F (0°C to 50°C) Storage temperature: -4°F to 158°F (-20°C to 70°C)
Vibration and ShockVibration: 4g (20 to 2,000 Hz) Shock: 8g, 1 meter drop test
ComplianceCE
SoftwareACal, PCal, Land, LogII
Warranty1 year