• Calibration of both temperature and pressure transmitters
  • Measure/source/simulate mA loop parameters
  • Measure and source mA, Volts DC, frequency, and resistance
  • Built-in 24 V loop power supply

  • Temperature control from 100°C to 1210°C
  • Two models to choose from: Reference (ADT878) and Standard (ADT875)
  • Display Accuracy of ±1.5°C (ADT878)
  • 4 on-board measurement channels (PC option)
  • Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
  • ISO 17025-accredited calibration w/data included

  • Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
  • Accuracy up to ±0.002 °C.
  • Quick sample readings in as little as 0.3 seconds.
  • 1524 has two channels for simultaneous measurements, doubling productivity.

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -80 °C to 300 °C ( -112 °F to 572 °F)
  • Displays temperature in °C or °F

  • Highly accurate thermo hygrometer and humidity monitor.
  • Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
  • Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
  • Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.

  • Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
  • Measures and simulates 13 different RTD types and resistance
  • Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
  • Comes with a magnetic hanging tool designed in for convenient hands-free operation
  • Features configurable 0% and 100% source settings for quick 25% linearity checks

  • World’s smallest portable calibration baths.
  • Calibrates sensors of any size or shape.
  • Stability to ±0.015 °C.
  • Ranges from –30 °C to 200 °C.

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C