Fluke 724 Temperature Calibrator

  • Powerful, easy-to-use, high-accuracy temperature calibrator
  • Test and calibrate temperature sensors and transmitters
  • Measures 4 to 20 mA loops and can provide loop power
  • Measures RTDs, thermocouples, ohms, and volts
  • Source/simulates thermocouples, RTDs, volts, and ohms

Fluke 9103/9140 Field Dry-Well

  • Accuracy to ±0.25°C and comes with an RS-232 interface.
  • The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
  • The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
  • Features designed with user convenience and productivity in mind.

, , ,

Fluke 726 Precision Multifunction Calibrators

  • Precision multifunction, temp, frequency, voltage, and mA calibrator
  • Calibrates thermocouples and RTD temperature instruments
  • Stores up to eight calibration results in memory for analysis
  • Built-in 24 V Loop Power Supply

Fluke 1502A/1504 Thermometer Readout

  • 1502A: accuracy up to ±0.006 °C.
  • 1504: accuracy up to ±0.002 °C plus ability to measure thermistor temperature sensors.
  • 1502A: covers –200°C to 962°C
  • 1504: covers 0 to 100°C

Additel ADT875 Dry Well Calibrator

  • Dual-zone control
  • Full HART field communicator
  • Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication
  • Set point control by reference
  • Self-calibration feature
  • ISO 17025-accredited calibration w/data included

Fluke 5608 and 5609 Secondary PRT with Calibration Options

  • 5608: –200 °C to 500 °C (80 mm minimum immersion)
  • 5609: –200 °C to 670 °C (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend

Fluke 9144 Metrology Well

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C

Fluke 9132/9133 Infrared Calibrator with Blackbody Source

  • Accurate, reliable performance from –15 °C to 500 °C
  • Small, compact design in a blackbody calibrator
  • These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm).
  • Intuitive, easy-to-read display that indicates when temperature is stable.

Fluke 9190A-X-P Ultra-Cool Field Metrology Well

  • Wide Temperature Range: Covers a broad temperature range from -95°C to 140°C, suitable for a wide variety of applications, including those requiring low-temperature calibration.
  • Portability: Remains compact and portable, allowing for on-site calibrations at various locations.