Fluke 9144 Metrology Well

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C

Fluke 9143 Field Metrology Well

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

Fluke 9150 Thermocouple Furnace

  • Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
  • With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
  • Low-cost thermocouple furnace.
  • NIST-traceable calibration included.
  • RS-232 port standard

Fluke 5606 Full Immersion PRT

  • Operate in temperatures ranging from -200 °C to 160 °C.
  • Accuracy of ± 0.05 °C.
  • Both the transition junction and lead wires of these PRTs can withstand the full PRT temperature range.
  • Unique probe seal prevents moisture ingress.
  • Come with NVLAP-accredited calibration.

Additel 850-1200 Laboratory Thermocouple Calibration Furnace

  • Temperature control from 300°C to 1200°C
  • 3-in-1 furnace with 9 unique modes
  • Stability of ±0.1°C
  • Radial uniformity of ±0.25°C @ 1200°C
  • Axial uniformity of ±0.25°C @ 1200°C

Fluke ITS-90 Fixed-Point Cells

  • Constructed using metal samples with purity of at least 99.9999 % (six 9s) and, in many cases, 99.99999 % (seven 9s).
  • Every ITS-90 fixed point available from argon to copper
  • Plateaus last days (gallium for weeks and TPW for months).
  • Accredited Cell Intercomaparisons available.

Fluke 1502A/1504 Thermometer Readout

  • 1502A: accuracy up to ±0.006 °C.
  • 1504: accuracy up to ±0.002 °C plus ability to measure thermistor temperature sensors.
  • 1502A: covers –200°C to 962°C
  • 1504: covers 0 to 100°C

Fluke 9172 Field Metrology Well

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

Fluke 1529 Chub-E4 Standards Thermometer

  • Supports four channels for PRTs, thermistors, and thermocouples, accommodating a variety of sensor types.
  • Display eight user-selected data fields from any channel.
  • Log up to 8,000 readings with date and time stamps for data tracking.