• Precision multifunction, temp, frequency, voltage, and mA calibrator
  • Calibrates thermocouples and RTD temperature instruments
  • Stores up to eight calibration results in memory for analysis
  • Built-in 24 V Loop Power Supply

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

  • Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
  • Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
  • Scan up to 10 channels per second, great for high-speed applications.
  • Four operation modes – Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
  • Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.

  • Dual-zone control
  • Full HART field communicator
  • Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication
  • Set point control by reference
  • Self-calibration feature
  • ISO 17025-accredited calibration w/data included

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C

  • Supports four channels for PRTs, thermistors, and thermocouples, accommodating a variety of sensor types.
  • Display eight user-selected data fields from any channel.
  • Log up to 8,000 readings with date and time stamps for data tracking.

  • Calibration of both temperature and pressure transmitters
  • Measure/source/simulate mA loop parameters
  • Measure and source mA, Volts DC, frequency, and resistance
  • Built-in 24 V loop power supply
  • Store and recall frequently used calibration set ups

  • Operate in temperatures ranging from -200 °C to 160 °C.
  • Accuracy of ± 0.05 °C.
  • Both the transition junction and lead wires of these PRTs can withstand the full PRT temperature range.
  • Unique probe seal prevents moisture ingress.
  • Come with NVLAP-accredited calibration.

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

  • Highly accurate, easy-to-use thermocouple temperature calibrator
  • Measures and simulates 17 thermocouple types and millivolts
  • Measures 4 to 20 mA signals while sourcing a temperature signal
  • Comes with a magnetic hanger for convenient hands-free operation
  • Features configurable source settings for quick linearity checks

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -80 °C to 300 °C ( -112 °F to 572 °F)
  • Displays temperature in °C or °F

  • Temperature ranges from –15 °C to 350 °C.
  • Two wells in each block for simultaneous comparison calibrations.
  • The cold block is calibrated to within ±0.2°C with stability of ±0.05°C. The hot block’s display is accurate to ±0.6°C with stability of ±0.05°C.
  • Rugged, lightweight, and water-resistant enclosure.

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • World’s smallest portable calibration baths.
  • Calibrates sensors of any size or shape.
  • Stability to ±0.015 °C.
  • Ranges from –30 °C to 200 °C.

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Reference level performance in accuracy, stability and uniformity
  • Quick to temperature
  • Two-channel readout measures RTDs and TCs, and provides task documentation
  • Full HART communicator (PC Option)
  • Built in automatic annealing feature (ADT878-700 only)
  • ISO 17025-accredited calibration w/data included

  • Temperature control from 300°C to 1200°C
  • 3-in-1 furnace with 9 unique modes
  • Stability of ±0.1°C
  • Radial uniformity of ±0.25°C @ 1200°C
  • Axial uniformity of ±0.25°C @ 1200°C

  • Temperature ranges from –10°C to 375°C.
  • Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
  • Equipped with an RS-232 interface for connectivity.

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

  • Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy.
  • Covers a wide temperature range: 6109A: 35 °C to 250 °C
  • 7109A: -25 °C to 140 °C.
  • Stainless steel casing that withstands harsh cleaning solutions; it’s easy to transport and maintain.

  • 5608: –200 °C to 500 °C (80 mm minimum immersion)
  • 5609: –200 °C to 670 °C (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend

  • Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
  • With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
  • Low-cost thermocouple furnace.
  • NIST-traceable calibration included.
  • RS-232 port standard

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Wide temperature range: –95 °C to 140 °C.
  • Excellent accuracy
  • Accuracy using built-in reference thermometer readout: ± 0.05 °C full range.
  • Display accuracy: ± 0.2 °C full range.
  • Best-in-class stability: ± 0.015 °C full range

  • Temperature ranges from –10°C to 375°C.
  • Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
  • Equipped with an RS-232 interface for connectivity.

  • Most stable temperature controllers available
  • Resolution as high as 0.00018°C
  • RS-232 interface included for automating applications

  • Powerful, easy-to-use, high-accuracy temperature calibrator
  • Test and calibrate temperature sensors and transmitters
  • Measures 4 to 20 mA loops and can provide loop power
  • Measures RTDs, thermocouples, ohms, and volts
  • Source/simulates thermocouples, RTDs, volts, and ohms

  • Full-featured documenting process calibrator for calibrating and troubleshooting
  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Temperature control from 100°C to 1210°C
  • Two models to choose from: Reference (ADT878) and Standard (ADT875)
  • Display Accuracy of ±1.5°C (ADT878)
  • 4 on-board measurement channels (PC option)
  • Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
  • ISO 17025-accredited calibration w/data included

  • Accredited radiometric calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large target size of 152 mm (6 in) is required for calibrating most thermometers.
  • Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.

  • Highly accurate thermo hygrometer and humidity monitor.
  • Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
  • Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
  • Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.