- Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
- Ideal for gas flow calibration (custody transfer) applications
- Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
- Pt100 RTD input for temperature measurement, (probe optional)
- Automatic pressure generation and regulation to 1000psi
- Extend measurement range with 750P Series pressure modules
- Measure temperature with 720RTD probe
- Absolute and gage pressure modules up to 7MPa.
- Use the modules to change the Fluke 729Pro to a different output pressure range
- Intrinsically safe multifunction process calibrator
- Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
- Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
- Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms
- Eliminates the need for weights and piston-cylinder changes.
- Real-time pressure indication without need for corrections.
- Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
- Offers ± 0.02% of reading total one-year measurement uncertainty
- Pressure ranges to 10,000 psi (700 bar)
- 0.015% of reading accuracy standard (0.008% optional)
- Single or dual piston formats
- Built-in hand pumps standard
- Mounted spirit level with adjustable feet
- Units can be trimmed to local gravity FOC
- 0.02% full scale accuracy per 2700G Gauge.
- Adaptors for NPT, BSP, and metric fittings.
- Expandable lower range with additional gauges.
- Battery-operated gauges with line power capability.
- Measure pressure, 0.05% of full scale with internal sensor up to 5000 psi/345 bar sensor (5000G model)
- Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
- Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
- 1/8 NPT female pressure fitting
- Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Powers transmitters during test using loop supply with simultaneous mA measurement
- A complete family of precision pressure modules
- Covers workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar)
- 8 intrinsically safe models for use with Fluke 718EX or 725EX
- Reduce errors by digitally sending measurements to calibrators
- Precision measurements with reference uncertainties up to 0.01%