• Eliminates the need for weights and piston-cylinder changes.
  • Real-time pressure indication without need for corrections.
  • Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
  • Offers ± 0.02% of reading total one-year measurement uncertainty

  • A complete family of precision pressure modules
  • Covers workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar)
  • 8 intrinsically safe models for use with Fluke 718EX or 725EX
  • Reduce errors by digitally sending measurements to calibrators
  • Precision measurements with reference uncertainties up to 0.01%

  • Complete pressure, temperature, and mA loop calibrator
  • Troubleshoot and calibrate HART smart digital transmitters
  • Create calibration procedures and automatically document results

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.

  • Calibration of both temperature and pressure transmitters
  • Measure/source/simulate mA loop parameters
  • Measure and source mA, Volts DC, frequency, and resistance
  • Built-in 24 V loop power supply

  • Pressure ranges to 10,000 psi (700 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston formats
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC

  • Precision multifunction, temp, frequency, voltage, and mA calibrator
  • Calibrates thermocouples and RTD temperature instruments
  • Stores up to eight calibration results in memory for analysis
  • Built-in 24 V Loop Power Supply

  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Eliminates the need for weights and piston-cylinder changes.
  • Real-time pressure indication without need for corrections.
  • Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
  • Offers ± 0.02% of reading total one-year measurement uncertainty.