Additel ADT761A Automated Pressure Calibrator

  • Automated and self-contained pressure generation and control to 1,500 psi ( 100 bar)
  • Precision accuracy models to 0.01%FS
  • Two removable internal pressure modules for multi-range selection
  • Control stability to 0.003%FS

Fluke 717 Pressure Calibrator

  • Measure pressure, 0.05% of full scale with internal sensor up to 5000 psi/345 bar sensor (5000G model)
  • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
  • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
  • 1/8 NPT female pressure fitting

, , ,

Fluke 754 Documenting Process Calibrator-HART

  • Complete pressure, temperature, and mA loop calibrator
  • Troubleshoot and calibrate HART smart digital transmitters
  • Create calibration procedures and automatically document results

Fluke P5510-2700G & P5513-2700G Pressure Calibrators

  • 0.02% full scale accuracy per 2700G Gauge.
  • Adaptors for NPT, BSP, and metric fittings.
  • Expandable lower range with additional gauges.
  • Battery-operated gauges with line power capability.

Fluke P3000 Pneumatic Deadweight Testers

  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC

Fluke 721 Pressure Calibration Instruments

  • Precision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications
  • Features two isolated, stainless steel, pressure sensors with 0.025% accuracy
  • Includes Pt100 RTD input for temperature measurement (probe optional)
  • Measures 4 to 20 mA signals
  • Provides internal 24 V loop power supply to power a transmitter under test

Additel ADT762 Automated Hydraulic Pressure Calibrator

  • Automated pressure generation and control to 15,000 psi (1035 Bar)
  • Accuracy to 0.01%FS
  • Dual-range calibration
  • Control stability ≤ 0.005%FS
  • Data logging and task management
  • Patented electric pump technology
  • ISO 17025-accredited calibration w/data included

Fluke P3031 and P3032 Pneumatic Deadweight Testers

  • Pressure ranges to 2000 psi (140 bar)
  • 0.015% of reading accuracy (0.008% optional)
  • Screw press for fine pressure control
  • Piston flotation indicator
  • Mounted spirit level with adjustable feet
  • Series 3 non-magnetic stainless steel weights

Fluke P5513 Pneumatic Comparison Test Pump

  • High pressure pneumatic operation
  • Screw press for fine pressure adjustments
  • High quality needle valves for fine control
  • Test port adapters which require no PTFE tape or wrenches
  • Sturdy carrying case with lid