Fluke 3130-G2M Portable Pressure Calibrator
- Measure/generate pressures from vacuum to 2 MPa (300 psi, 20 bar).
- Measure/generate 4 to 20 mA, measures 0 to 30 V DC
- Generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar).
- External gas supply up to 2 MPa (300 psi, 20 bar).
- Fine pressure adjustment.
- Measurement accuracy of ± (0.025 % reading + 0.01 % FS).
Fluke P5513 Pneumatic Comparison Test Pump
- High pressure pneumatic operation
- Screw press for fine pressure adjustments
- High quality needle valves for fine control
- Test port adapters which require no PTFE tape or wrenches
- Sturdy carrying case with lid
Fluke 6531 and 6532 E-DWT Electronic Deadweight Tester Kits
- Eliminates the need for weights and piston-cylinder changes.
- Real-time pressure indication without need for corrections.
- Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
- Offers ± 0.02% of reading total one-year measurement uncertainty.
Fluke 750P Series Pressure Modules
- A complete family of precision pressure modules
- Covers workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar)
- 8 intrinsically safe models for use with Fluke 718EX or 725EX
- Reduce errors by digitally sending measurements to calibrators
- Precision measurements with reference uncertainties up to 0.01%
Fluke 718Ex Intrinsically Safe Pressure Calibrator
- ATEX II 1G Ex ia IIC T4 Compliant.
- 30, 100, and 300 psi ranges (2, 7, and 20 bar)
- Pressure measurement to 0.05% of full span, using an internal pressure sensor.
- Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
- Current measurement with 0.02% accuracy and 0.001 mA resolution.
Fluke 725 Multifunction Process Calibrator
- Calibration of both temperature and pressure transmitters
- Measure/source/simulate mA loop parameters
- Measure and source mA, Volts DC, frequency, and resistance
- Built-in 24 V loop power supply
Fluke P5510-2700G & P5513-2700G Pressure Calibrators
- 0.02% full scale accuracy per 2700G Gauge.
- Adaptors for NPT, BSP, and metric fittings.
- Expandable lower range with additional gauges.
- Battery-operated gauges with line power capability.
Fluke 729 Pro Automatic Pressure Calibrator
- Automatic pressure generation and regulation to 1000psi
- Extend measurement range with 750P Series pressure modules
- Measure temperature with 720RTD probe
- Absolute and gage pressure modules up to 7MPa.
- Use the modules to change the Fluke 729Pro to a different output pressure range
Fluke 753 Documenting Process Calibrator
- Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Powers transmitters during test using loop supply with simultaneous mA measurement








