CONTACT US

This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Jakarta Office : 021-45850618


Surabaya Office : 031-8421264

 
Fluke 435 Series II Energy Analyzer

Features

Power quality issues can affect the operation of critical loads and have a negative impact on your bottom line. Think of the Fluke 435 II Power Quality and Energy Analyzer as your insurance policy. The Fluke 435 Series II Power Quality and Energy Analyzer is the world's only Power Quality analyzer that can monetize the cost of energy waste due to poor power quality. The wide range of measurement functions and measurement methods in the Fluke 435-II make it the ideal tool for both power quality troubleshooting and discovering energy savings Whether you’re checking the performance of motors and generators, trying to discover the source of an intermittent power problem or performing an energy study the Fluke 435-II will give you the data you need to quickly get to the heart of the problem.

  • Troubleshoot Real-Time: Analyze the trends using the cursors and zoom tools.
  • Automatic Trending: Every measurement is always automatically recorded, without any set-up.
  • Logger Function: Configure for any test condition with memory for up to 600 parameters at user defined intervals.
  • Measure All Three Phases and Neutral: With included four flexible current probes with enhanced thin flex design to fit into the tightest places.
  • PowerWave Data Capture: Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
  • Power Inverter Efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
  • Energy Loss Calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses.
  • Highest Safety Rating in the Industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
  • System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
  • View Graphs and Generate Reports: With included analysis software.
  • Battery Life: Seven hours operating time per charge on Li-ion battery pack.

 

Specs

Product Specifications

Volt Model Measurement Range Resolution Accuracy
Vrms (AC + DC) 1 V to 1000 V phase to neutral 0.01 V ±0.1% of nominal voltage1
Vpk 1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
Voltage Crest Factor (CF) 1.0 > 2.8 0.01 ±5%
Vrms½   0.1 V ±0.2% of nominal voltage
Vfund   0.1 V ±0.1% of nominal voltage

Amps (accuracy excluding clamp accuracy)

Amps (AC + DC) i430-Flex 1x 5 A to 6000 A 1 A ±0.5% ±5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
1mV/A 1x 5 A to 2000 A 1A ±0.5% ±5 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
Apk i430-Flex 8400 Apk 1 Arms ±5%
1mV/A 5500 Apk 1 Arms ±5%
A Crest Factor (CF) 1 to 10 0.01 ±5%
Amps½ i430-Flex 1x 5 A to 6000 A 1 A ±1% ±10 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±1% ±10 counts
1mV/A 1x 5 A to 2000 A 1 A ±1% ±10 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±1% ±10 counts
Afund i430-Flex 1x 5 A to 6000 A 1 A ±0.5% ±5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
1mV/A 1x 5 A to 2000 A 1 A ±0.5% ±5 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts

Hz

Fluke 434 @ 50 Hz Nominal 42.50 Hz to 57.50 Hz 0.01 Hz ±0.01 Hz
Fluke 434 @ 60 Hz Nominal 51.00 Hz to 69.00 Hz 0.01 Hz ±0.01 Hz

Power

Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ±1% ±10 counts
1 mV/A max 2000 MW 0.1 W to 1 MW ±1% ±10 counts
Power Factor (Cos j/DPF) 0 to 1 0.001 ±0.1% @ nominal load conditions

Energy

kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts
Energy Loss i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts Excluding line resistance accuracy

Harmonics

Harmonic Order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-Harmonic Order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
Absolute 0.0 to 1000 V 0.1 V ±5%1
THD 0.0% to 100% 0.1% ±2.5%
Amps % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
Absolute 0.0 to 600 A 0.1 A ±5% ±5 counts
THD 0.0% to 100% 0.1% ±2.5%
Watts % f or r 0.0% to 100% 0.1% ±n x 2%
Absolute Depends on clamp scaling and V nominal ±5% ±n x 2% ±10 counts
THD 0.0% to 100% 0.1% ±5%
Phase Angle -360° to +0° ±n x 1°

Flicker

Plt, Pst, Pst (1 min) Pinst 0.00 to 20.00 0.01 ±5%

Unbalance

Volts % 0.0% to 20.0% 0.1% ±0.1%
Amps % 0.0% to 20.0% 0.1% ±1%

Mains Signaling

Threshold Levels Threshold, limits and signaling duration is programable for two signaling frequencies
Signaling Frequency 60 Hz to 3000 Hz 0.1 Hz  
Relative V % 0% to 100% 0.10% ±0.4%
Absolute V3s (3 second avg.) 0.0 V to 1000 V 0.1 V ±5% of nominal voltage

General Specifications

Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory 8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32 GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-Time Clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture

Environmental

Operating Temperature 0°C ~ +40°C; +40°C ~ +50°C excl. battery
Storage Temperature -20°C ~ +60°C
Humidity +10°C ~ +30°C: 95% RH non-condensing
+30°C ~ +40°C: 75% RH non-condensing
+40°C ~ +50°C: 45% RH non-condensing
Maximum Operating Altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
 
1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if < 1% of nominal voltage
2. 50Hz/60Hz nominal frequency according to IEC 61000-4-30
3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode
4. For nominal voltage 50 V to 500 V

Models

Model Name Consist of Price
FLUKE 435 II
  • Fluke 435 II
  • BC430 Power Adapter
  • International Plug Adapter Set
  • BP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)
  • TLS430 Test Lead and Alligator Clip Set
  • WC100 Color Coding Clips and Regional Decals
  • i430flex-TF-II, 24 inch (61 cm) Length, 4 Flexible Current Probes
  • 8 GB SD Card
  • PowerLog on CD (includes operator manuals in PDF format)
  • USB Cable A - Mini B
  • Soft Carrying Bag
Get a Quote
FLUKE 435 II
  • Fluke 435 II BASIC
  • BC430 Power Adapter
  • International Plug Adapter Set
  • BP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)
  • TLS430 Test Lead and Alligator Clip Set
  • WC100 Color Coding Clips and Regional Decals
  • 8 GB SD Card
  • PowerLog on CD (includes operator manuals in PDF format)
  • USB Cable A - Mini B
Get a Quote

Brochures

-

Power Quality Software Downloads

To ensure your product has the latest software release that include new features, click on the appropriate link below and follow the download instructions.

Fluke 430 Series II Three-Phase Energy and Power Quality Analyzers

Download

Last updated

Firmware Update V05.00 (.exe) »
The application requires a COM port number to be selected, this information can be found in Windows device manager device list. The application provides step by step instructions. Important: Please read HELP text in upgrader before proceeding.

06/2016

Firmware Update V05.00 Release Notes (.pdf) »
Complete details of the benefits of updating to V05.00. These notes are important to ensure save preservation of existing data, consult the short guide on data backup if in doubt.

06/2016

PowerLog430-II Application Software V5.2 for Fluke 430 Series II (.exe) »
PowerLog Application software for Fluke Power Quality analyzers 430-II, only.

06/2016

PowerLog430-II V5.2 Release Information (.pdf) »
Complete details of new features and bug fixes – it is important to read these notes.

06/2016

Backing Up and Copying Data from the Fluke 430 (.pdf) »
A short guide on backing up the important data on your instrument. Also includes guidance on data archiving.

9/2012

Fluke 430 Series II USB driver (.zip) »
The Fluke 430 Series II USB driver will install automatically under normal circumstances. This file is for manual installation when Internet access is not available.

 

Ladbrokes Review L.BetRoll
Top United Kingdom Bookmakers http://betroll.co.uk/