Fluke 773 Milliamp Process Clamp Meter
- Measure 4 to 20 mA signals without breaking the loop
- Source/simulate 4 to 20 mA signals and provide loop power
- Source/measure DC voltage to verify power supplies or I/O signals
- Best in class accuracy of 0.2%
- Delivers 0.01 mA resolution and sensitivity
- Description
- Additional information
- Specifications
Description
The Fluke 773 Milliamp Process Clamp Meter is a specialized tool designed for efficient and accurate testing and troubleshooting of 4-20 mA current loops in industrial process control systems.
Key Features:
- Measure 4 to 20 mA signals without breaking the loop
- Source/simulate 4 to 20 mA signals and provide loop power
- Source/measure DC voltage to verify power supplies or I/O signals
- Best in class accuracy of 0.2%
- Delivers 0.01 mA resolution and sensitivity
- Non-Invasive Measurement: The 773 uses a clamp-on design, allowing you to measure the current flowing through a conductor without breaking the loop. This eliminates the need to disconnect wires, minimizing downtime and reducing the risk of errors.
- Fast and Accurate Measurements: The 773 provides fast and accurate measurements of 4-20 mA signals, allowing for quick troubleshooting and calibration.
- Versatility: In addition to mA loop measurements, the 773 can also measure AC/DC voltage, resistance, and frequency.
- User-Friendly Interface: Features an intuitive interface with a clear display for easy operation and data interpretation.
- Rugged and Durable: Designed to withstand harsh industrial environments and provide reliable performance in demanding conditions.
Applications:
- Process Instrumentation: Troubleshooting and calibration of 4-20 mA transmitters, sensors, and control loops in industrial plants.
- Predictive Maintenance: Identifying potential problems within 4-20 mA loops before they lead to equipment failures or production disruptions.
- Electrical Troubleshooting: Diagnosing electrical issues in industrial equipment and systems.
- Process Optimization: Ensuring accurate and reliable signal transmission within process control systems.
In Summary:
The Fluke 773 Milliamp Process Clamp Meter is a valuable tool for technicians and engineers working with 4-20 mA loops. Its non-invasive measurement capabilities, speed, accuracy, and rugged design make it an efficient and reliable solution for troubleshooting, maintaining, and optimizing industrial processes.
Additional information
Brand | Fluke Calibration |
---|
Specifications: Fluke 773 Milliamp Process Clamp Meter
Specifications | ||
Diameter of measurable conductor | 0.177″ or 4.5 mm max | |
Operating temperature | -10 to 50ºC | |
Storage temperature | -25 to 60ºC | |
Operating humidity | < 90% @ <30ºC, < 75% @ 30 to 55ºC | |
Operating altitude | 0 to 2000 m | |
IP rating | IP 40 | |
Size | 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) | |
Weight | 410 g, (14.4 oz) | |
Vibration | Random 2 g, 5 to 500 Hz | |
Shock | 1 meter drop test (except the jaw) | |
EMI/RFI | Meets EN61326-1 | |
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. | ||
Temperature coefficient | 0.01% ºC (< 18ºC or > 28ºC) |
|
Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms | |
Warranty | Three years for electronics One year for cable and clamp assembly |
|
Functional Specifications | ||
mA measurement (measured by clamp) |
Resolution / range | 0 to 20.99 mA |
Accuracy | 0.2% + 5 counts | |
Resolution / range | 21.0mA to 100.0 mA | |
Accuracy | 1% + 5 counts | |
mA measurement (measured in series with test jacks) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA source (maximum mA drive: 24 mA into 1,000 ohms) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA simulate (maximum voltage 50 V dc) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
Voltage source (2 mA maximum drive current) | Resolution / range | 0 to 10.00 V DC |
Accuracy | 0.2% + 2 counts | |
Voltage measure | Resolution / range | 0 to 30.00 V DC |
Accuracy | 0.2% + 2 counts |