Fluke 6531 and 6532 E-DWT Electronic Deadweight Tester Kits

  • Eliminates the need for weights and piston-cylinder changes.
  • Real-time pressure indication without need for corrections.
  • Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
  • Offers ± 0.02% of reading total one-year measurement uncertainty.

Description

The Fluke Calibration 6531 and 6532 E-DWT are electronic deadweight testers designed for hydraulic pressure calibration. They offer a combination of precision, ease of use, and portability, making them suitable for both laboratory and field applications.

Key features and benefits:

  • Eliminates the need for weights and piston-cylinder changes.
  • Real-time pressure indication without need for corrections.
  • Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
  • Offers ± 0.02% of reading total one-year measurement uncertainty.
  • Electronic pressure measurement: Provides continuous, real-time pressure readings, eliminating the need for manual calculations and corrections.
  • Manual pressure generation and control: Offers precise control over pressure generation using a hand pump and variable volume.
  • Portability: Compact and lightweight design makes them easy to transport and use in the field.
  • Wide pressure range: Capable of generating pressures up to 200 MPa (30,000 psi), depending on the configuration.
  • Versatility: Compatible with a variety of test fluids, including oil, water, and other liquids.

Applications:

  • Calibration of pressure gauges, transmitters, and switches
  • Process control
  • Hydraulic system testing
  • Research and development

Overall, the Fluke Calibration 6531 and 6532 E-DWT are powerful and versatile tools for accurate and efficient hydraulic pressure calibration.

Additional information

Brand

Fluke Calibration

Specifications: Fluke Calibration 6531, 6532 E-DWT Electronic Deadweight Tester Kits

General
Power requirements
To RPM4-E-DWT: 12 V dc 1.2 A
To AC to DC power supply: 100 V ac to 240 V ac, 50/60 Hz
Temperature range
Storage: – 20 °C to 70 °C
Operating: 10 °C to 40 °C
Relative Humidity
Storage: 0 % to 100 %
Operating: 0 % to 70 %
Weight
1 Q-RPT: 12 kg (26 lb) approximate
2 Q-RPT: 14 kg (30 lb) approximate
Dimensions
E-DWT footprint: 41.4 cm W x 37.1 cm D (16.3 in x 14.6 in)
E-DWT height: 26.9 cm (10.6 in), 33.6 cm (13.2 in) to max variable volume handle height
Pressure range Up to 200 MPa (30k psi), depending on configuration
Operating medium All 6531 and 6532 E-DWT Kits are shipped dry, standard preparation. Can be filled with di-ethyl-hexyl sebacate, silicon oils, propylene glycol, fully fluorinated liquids, partially fluorinated liquids, isopropyl alcohol and distilled water or mineral oil.
Reservoir capacity 300 cc (18 in3)
Variable volume displacement 3 cc (0.18 in3), 200 MPa (30,000 psi) maximum
Filling and priming pump displacement 3.7 cc (0.23 in3)
TEST pressure connection DH500 female, 200 MPa (30k psi) maximum working pressure. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5. Adapter maximum working pressure is 140 MPa (20k psi). Note: DH500 is a gland and collar type fitting for 6 mm (1/4 in) coned and left hand threaded tubes equivalent to AE F250C, HIP HF4, 9/16-18 UNF, etc.
Pressure Limits
Maximum Working Pressure: Range of RPM4-E-DWT monitor’s Hi Q-RPT
Maximum priming pump pressure: 700 kPa (100 psi)
Maximum Working Pressure: with Lo Q-RPT selected: Range of RPM4-E-DWT monitor’s Lo Q-RPT
Communication ports: RS-232 (COM1, COM2)
Pressure measurement
Warm up time 15 minute temperature stabilization recommended from cold power up
Normal Operating Temperature Range 10 °C to 40 °C (50 °F to 104 °F)
Resolution Default: 0.01 % of active range
User adjustable to 1 ppm of Q-RPT maximum or 10 ppm of active AutoRange, whichever is larger
Precision1 200 MPa (30,000 psi) ranges:  ± 0.018 % of reading or 0.0036 % of Q-RPT span, whichever is greater

All other ranges:  ± 0.018 % of reading or 0.0018 % of Q-RPT span, whichever is greater

Predicted Stability2
One year: ± 0.0075 % of reading
Two year: ± 0.015 % of reading
Measurement Uncertainty3
One year: 200 MPa (30,000 psi) ranges:  ± 0.02 % of reading or 0.004 % of Q-RPT span, whichever is greater

All other ranges:  ± 0.02 % of reading or 0.002 % of Q-RPT span, whichever is greater

Two year: 200 MPa (30,000 psi) ranges:  ± 0.025 % of reading or 0.005 % of Q-RPT span, whichever is greater

All other ranges:  ± 0.025 % of reading or 0.0025 % of Q-RPT span, whichever is greater

 

Related Products