Vitrek 964i High Voltage Switching System

Features

The Perfect Solution for Automated Multi-Conductor, Multi-Point Hipot Testing

You have a job to do – you have to hipot test a 16 conductor medical cable at 8500V to ensure that each conductor is properly isolated from every other conductor. You have two choices, you can try to do it manually or you can use the Vitrek 964i to automatically route the HV and return signals to the proper test points.

The manual method is extremely problematic. Slow, error prone, labor intensive, operator hazardous – don’t even think about recording the test results. The 964i on the other hand, is purpose built to fully automate all of you HV switching needs. You chose the 964i, partnered it with a Vitrek 95X Series Industrial Strength Hipot Tester and QuickTest Pro test automation software.

  • High Voltage Ratings to 3KV, 7KV, 10KV or 15KV
  • High Current Ratings to 40 Amps
  • Reduces hazardous operator exposure to high voltage
  • Improves test quality, consistency and repeatability
  • Enhances end product quality and reliability
  • Up to 64 channels in a single compact unit
  • Vitrek Hipot Tester control ports and RS232 interfaces standard
  • GPIB optionally available
  • May be controlled directly by Vitrek Hipot Tester
  • Available QuickTest™ graphical software with full data aquisition
  • CE mark certified to EN 61010

Specs

For full specifications, please contact us

Specifications

HV Series Relay Boards

Max Voltage
(Between any two connections or ground)
HV7: 7KVDC 5KVAC, HV10: 10KVDC 7KVAC, HV15: 15KVDC 10KVAC
Frequency: <500Hz.
Carrying Current: Switching Power: HV7 and HV10: Switching Time: Expected Life: <1mA, Contact Resistance: At terminals, <50% expected life operations (add 0.1Ω for <100% life)
<0.25Ω (uncompensated), <0.1Ω (compensated), <±0.1Ω difference between lowest and highest.
Leakage Resistance: Any individual connection to ground: >500GΩ at 100GΩ at 1TΩ at <30C.
Leakage Capacitance: Any individual connection to ground: 15pF (typical). Common connection to ground: 50pF (typical). Between any two connections: 5pF (typical).
Thermal EMF: <1mV.
Coil Power: Holding closed: 0.3W (typical), Closing: 1.25W for 5ms (typical)

LV Series Relay Boards

Max Voltage
(Between any two connections) 3KVDC 2KVAC
(between any connection and ground) 5KVDC 3KVAC
Frequency: <500Hz.
Carrying Current: Switching Power: Switching Time: Expected Life: <1mA, Contact Resistance: At terminals, <50% expected life operations (add 0.05Ω for <100% life)
<0.175Ω (uncompensated), <0.05Ω (compensated), <±0.075Ω difference between lowest and highest.
Leakage Resistance: Any individual connection to ground: >1GΩ at 200MΩ at 1GΩ at <30C.
Leakage Capacitance: Any individual connection to ground: 15pF (typical). Common connection to ground: 50pF (typical). Between any two connections: 10pF (typical).
Thermal EMF: <200uV.
Coil Power: Holding closed: 0.12W (typical), Closing: .5W for 5ms (typical)

HC Series Relay Boards

High Current Relay Specifications –

Max Voltage:
Between any two connections: 1.5KVdc/1KVrms.
Any connection to ground: 1.5KVdc/1KVrms.
Frequency: <500Hz.
Carrying Current: Switching Power: Min Switching Current: >0.5Arms.
Switching Time: Expected Life: 1 to 10Arms resistive 500,000 operations. At max power: 10,000 operations.
Contact Resistance: <0.025Ω (at terminals, <100% expected life operations).
Leakage Resistance: Any individual connection to ground: >20MΩ at 5MΩ at 20MΩ at <30C.
Coil Power: Holding closed: 0.6W (typical), Closing: 2.5W for 25ms (typical)

Low Current Relay Specifications –

Max Voltage: Between any two connections: 1.5KVdc/1KVrms. Any connection to ground: 1.5KVdc/1KVrms.
Frequency: <500Hz.
Carrying Current: Switching Power: Switching Time: Expected Life: <1mA, Contact Resistance: At terminals, <50% expected life operations (add 0.05Ω for <100% life), <0.15Ω (uncompensated), <0.05Ω (compensated).
Leakage Resistance: Any individual connection to ground: >100GΩ at 10GΩ at 100GΩ at <30C.
Leakage Capacitance: Any individual connection to ground: 15pF (typical). Common connection to ground: 50pF (typical). Between any two connections: 10pF (typical)
Thermal EMF: <100uV.
Coil Power: Holding closed: 0.06W (typical), Closing: 0.25W for 5ms (typical)

General Specifications

Relay Card Capacity: Eight cards
Front input Terminals: 5 inputs terminals
Rear Panel Terminals: 60 terminals
Interfaces:RS232 and VICL (Vitrek Hipot Control) standard, GPIB optional
Nominal Dimensions: 89mmH x 432mmW x 457mmD (3.5” x 17” x 18”)
Nominal Weight: Mainframe only 3.5Kg (8lb) net, 7Kg (16lb) shipping. Add 0.75Kg (1.5lb) per relay card
Storage Environment: -20 to 75C (non-condensing)
Operating Environment: 0 to 50C, <85% RH (non-condensing), Pollution Degree 2
Operating Altitude: 0 to 10000ft ASL
Line Power: 105-265Vrms, 45 to 450Hz, Category II using provided external power module

Models

Model Name Description Price
964i Hipot High Voltage Switching System Mainframe (No cards included). Comes with: Interconnect Lead Set (for connection to Vitrek Tester), Chassis Grounding Cable, VICL-2, External Power Supply with Power Cord, Operating Manual, Certificate of Quality.
964i-8X2MX Pre-built 964i with 2xHV7-8 (1 White, 1 Black) Cards and a Hipot/Cont Mux Card. Comes with: Interconnect Lead Set (for connection to Vitrek Tester), Chassis Grounding Cable, VICL-2, 8xHVC-MW, 8xHVC-MB, External Power Supply with Power Cord, Operating Manual, Certificate of Quality.
964i-16X2MX Pre-built 964i with 4xHV7-8 (2 White, 2 Black) Cards and a Hipot/Cont Mux Card. Comes with: Interconnect Lead Set (for connection to Vitrek Tester), Chassis Grounding Cable, VICL-2, 16xHVC-MW, 16xHVC-MB, External Power Supply with Power Cord, Operating Manual, Certificate of Quality.
964i-24X2MX Pre-built 964i with 6xHV7-8 (3 White, 3 Black) Cards and a Hipot/Cont Mux Card. Comes with: Interconnect Lead Set (for connection to Vitrek Tester), Chassis Grounding Cable, VICL-2, 24xHVC-MW, 24xHVC-MB, External Power Supply with Power Cord, Operating Manual, Certificate of Quality.


Accessories

Model Name Description Price
LV3-8R 3kV Single Input Bus 8 Output Card with Red Banana Jack Terminals. Comes with: 8xRed Male Sheathed Banana Connectors.
LV3-8B 3kV Single Input Bus 8 Output Card with Black Banana Jack Terminals. Comes with: 8xBlack Male Sheathed Banana Connectors.
LV3-8S 3kV Two Single Input Bus 4 Output Card with Black and Red Banana Jack Terminals.Comes with: 4xRed Male Sheathed Banana Connectors and 4xBlack Male Sheathed Banana Connectors.
LV3-MX2 3kV Dual Input (HV/Cont) Single Output (+) Bus.
H7-8WV 7kV Single Input Bus 8 Output Card with White HV Terminals. Comes with: 8xHVC-MW.
HV7-8B 7kV Single Input Bus 8 Output Card with Black HV Terminals. Comes with: 8xHVC-MB.
HV7-8S 7kV Dual Single Input Bus 4 Output Card with Black and White HV Terminals. Comes with: 4xHVC-MW and 4xHVC-MB.
HV7-MX2 7kV Dual Input (HV/Cont) Single Output (+) Bus.
HV10-8W 10kV Single Input Bus 8 Output Card with White HV Terminals. Comes with: 8xHVC-MW.
HV10-8B 10kV Single Input Bus 8 Output Card with Black HV Terminals. Comes with: 8xHVC-MB.
HV10-8S 10kV Dual Single Input Bus 4 Output Card with Black and White HV Terminals. Comes with: 4xHVC-MW and 4xHVC-MB
HV10-MX2 10kV Dual Input (HV/Cont) Single Output (+) Bus.
HV15-8W 15kV Single Input Bus 8 Output Card with White HV Terminals. Comes with: 8xHVC-MW.
HV15-8B 15kV Single Input Bus 8 Output Card with Black HV Terminals. Comes with: 8xHVC-MB.
HV15-8S 15kV Dual Single Input Bus 4 Output Card with Black and White HV Terminals. Comes with: 4xHVC-MW and 4xHVC-MB.
HV15-MX2 15kV Dual Input (HV/Cont) Single Output (+) Bus.
HC-4B 4 Channel 30A Source & Sense Relay Card, Black.
HC-4R 4 Channel 30A Source & Sense Relay Card, Red.
HC-7B 4 Channel 70A Source & Sense Relay Card, Black.
HC-7R 4 Channel 70A Source & Sense Relay Card, Red.
GP-964 GPIB Interface Option for the 964i.
HVC-MW Male HV Mating Connector, White.
HVC-MB Male HV Mating Connector, Black.
HVC-FW Female HV Panel Mount Connector, White.
HVC-FB Female HV Panel Mount Connector, Black.
TL-HVW 20kV Rated 18 AWG Test Lead 4ft, MVC-MW to Alligator Clip.
TL-HVB 20kV Rated 18 AWG Test Lead 4ft, MVC-MB to Alligator Clip.
   
HVW-20 Bulk 20kV Rated 18 AWG Test Lead Wire, price per foot.
HVW-50 Bulk 50kV Rated 22 AWG Test Lead Wire, price per foot.
PB-7 Power Brick. Replacement External Power Source for the 4700 and 964i.
VICL-2 Replacement Vitrek Hipot Communication Cable. 7ft
USB-2 USB A to RS232 (Serial) Adapter Cable (Requires RS-2)
RS-2 Female to Female Null Modem RS232 (Serial) Cable 6ft
GP-1 1 Meter Shielded GPIB (IEE-488) Cable

 