CONTACT US

This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Jakarta Office :

021-45850618


  Surabaya Office :   

031-8421264

 
Vitrek 4700 Pecision High Voltage Meter

Features

The Vitrek 4700 Precision High Voltage Meter offers the highest level of measurement accuracy, yet with its color touch screen – is surprisingly easy to use. Vitrek leverages DSP technology to provide outstanding AC &DC voltage measurement accuracy, stability, repeatability and resolution. The 4700 High Voltage Meter offers performance that rivals traditional high voltage reference dividers – yet unlike the tedious divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure.

The 4700 Precision High Voltage Meter measures up to 10KV DC or rms AC directly and with available HV Smartprobes, the measurement range can be extended to 35KV, 70 KV, 100KV and 140KV.

  • Calibrates Hipot Testers, HV Power Supplies and Insulation Testers
  • Measures up to 10KV directly and 35, 70 , 100 or 150KV with HV Smartprobes
  • Basic Accuracy – 0.03% DC and 0.1% True RMS AC
  • Color Touch Screen – Makes for Easy Measurement Selection and Display
  • Ethernet, Serial, USB Printer Port all standard, GPIB optional
  • Simultaneous AC & DC Voltage Readings
  • Chart Mode provides Graphic documentation of HV drift, ramp time, overshoot and sag
  • Dual inputs allows Differential or Phase to Phase Voltage Measurement
  • High Speed DSP provides up to 60 filtered readings per second
  • True RMS AC Measurement from 0.01Hz to 600Hz – Covering VLF to Aviation Frequencies
  • AC Noise Rejection 78dB – For Rock Solid, 6 Digit DC Measurements
  • Optional Battery Pack goes up to 11 hours between charges
  • G Series – High Input Impedance Probes for Electrostatic applications
  • CE mark Certified to EN61010
  • Standard ISO 17025 Accredited Calibration comes standard with all 4700 units and probes

Specs

 

For full specifications, please contact us

Maximum Voltage Measurement (Input Impedance)
Direct Input Terminal 10KVDC, 10KVACrms (110 Meg ohms)
HVL-35 / HVP-35 Probe 35KVDC, 30KVACrms (200 Meg ohms)
HVL-35G Probe 35KVDC (10 Gig ohms)
HVL-70 Probe 70KVDC, 50KVACrms (400 Meg ohms)
HVL-70G Probe 70KVDC (20 Gig ohms)
HVL-100 Probe 100KVDC, 75KVACrms (600 Meg ohms)
HVL-100G Probe 100KVDC (30 Gig ohms)
HVL-150 Probe 140KVDC, 100KVACrms (1000 Meg ohms)

 

DC Voltage Measurement Accuracy (Resolution)
Direct Input Terminal 0.03% of reading + 0.03V (10mV)
HVL-35 / HVP-35 Probe 0.035% of reading + 0.07V (100mV)
HVL-35G Probe 0.25% of reading + 1.5V (1V)
HVL-70 Probe 0.04% of reading + 0.2V (1V)
HVL-70G Probe 0.35% of reading + 3.5V (1V)
HVL-100 Probe 0.05% of reading + 0.3V (1V)
HVL-100G Probe 0.5% of reading + 15 (10V)
HVL-150 Probe 0.08% of reading + 0.7V (10V)

 

AC Voltage Measurement Accuracy (Resolution)
Direct Input Terminal 0.12% of reading + 0.1V (10mV)
HVL-35 / HVP-35 Probe 0.1% of reading + 0.2V (100mV)
HVL-70 Probe 0.1% of reading + 0.4V (1V)
HVL-100 Probe 0.1% of reading + 0.6V (1V)
HVL-150 Probe 0.5% of reading + 1V (10V)

 

High Voltage Self Heating Effect
Direct Input Terminal 1.5 ppm of reading per KV2
HVL-35 / HVP-35 Probe 0.4 ppm of reading per KV2 / 0.75 ppm of reading per KV2
HVL-70 Probe 0.14 ppm of reading per KV2
HVL-100 Probe 0.14 ppm of reading per KV2
HVL-150 Probe 0.2 ppm of reading per KV2

 

General Specifications
AC/DC Voltage Measurement Resolution Selectable 4, 5 or 6 digits
Measurement Functions DC Voltage, True RMS AC Voltage, Ripple, Peak to Peak, Crest Factor & Frequency Measurement (4 digits 0.01 Hz to 600Hz)
Measurement Time Selectable down to 16mS (60 readings per sec.)
Maximum Input to Common Terminal 3 KV Peak for 1 sec, no damage
Accuracy Specifications Valid one year ± 5C from Cal temperature
Interfaces LAN (Ethernet), RS232/Serial and USB printer port standard. GPIB optional.

 

Environmental/Physical
Operating Environment 0 to 50C, <85% RH (non-condensing)
Dimensions 218mm (8.5″) wide x 130mm (5″) high x 253mm (10″) deep, nominally
Weight 2.4kg max (4kg shipping)

 

Power
AC Source 45 to 450Hz, 100 to 265Vrms at
DC Source 11 to 16Vdc at <1.2A, using a center positive 2.5mm DC power connector
BP-47 Battery Option Up to 11 hours continuous operation

 

Standard Accessories

The 4700 is shipped with an ISO 17025 cal cert with data and uncertainties, direct input test leads, chassis ground lead, operator’s manual, and external power supply. All probes ship with an ISO 17025 cal cert with data and uncertainties. The HVP handheld probes comes with a detachable probe tip and the HVL series probes ship with a toroid corona shield.

Models

Model Name Description Price
4700 Precision High Voltage Meter. The 4700 measures directly to 10KV AC & DC. Select one or more HV Smartprobes to extend this range. Comes with: TL-47, Operating Manual, External Power Supply with Power Cord, and ISO 17025 accredited certification of calibration with data and uncertainties.


Accessories

Model Name Description Price
BP-47 Internal Battery Pack. Adds an internal lithium-ion battery pack to the 4700 which will provide hours of operating time from a full charge. Charging is automatic when connect to the 4700 external power supply.
GP-47 Adds a GPIB (IEEE-488) interface to the 4700. GPIB connector is rear panel mounted.
HC-47 Hard Carrying Case. The HC-47 is a tough, durable hard shipping/carrying case with internal die cut foam inserts with room for a 4700 and accessories (including room for an HVP-35). External dimensions are 20” W x 17” D x 9” H.
RM-47 Rack Mount Kit. The RM-47 is a 3U (5.25”) high by 19” wide rack mount kit which is fastened directly to the 4700 extruded aluminum chassis. Panel mount handles are included.
RM-47D Dual Unit Rack Mount Kit. The RM-47D is a 3U (5.25”) high by 19” wide rack mount kit with panel and tray for mounting two 4700 units side by side.
HVP-35 Handheld 35KV High Voltage Probe. The HVP-35 is a handheld high voltage probe which connects to the 4700 probe input to extend the measurement range up to 35 KV. It is supplied with an ISO 17025 accredited certificate of calibration with data and uncertainties, detachable metal probe tip, and probe stand. Overall length is 370mm with probe tip. Cable length 1.8m.
HVL-35 Lab Precision 35KV High Voltage Probe. The HVL-35 is a bench top high voltage probe which connects to the 4700 probe input to extend the measurement range up to 35KV. It is supplied with an ISO 17025 accredited certificate of calibration with data and uncertainties and a detachable toroid corona shield. Overall height is 240mm with 1.8m cable.
HVL-35G Lab High Impedance 35KV High Voltage Probe. The HVL-35G is a high impedance bench top high voltage probe which connects to the 4700 probe input to extend the measurement range of the 4700 up to 35KV. Its higher impedance allows it to be used in electrostatic voltmeter applications. It is supplied with an ISO 17025 accredited certificate of calibration with data and uncertainties and a detachable toroid corona shield. Overall height is 240mm with 1.8m cable.
HVL-70 Lab Precision 70kV Probe. The HVL-70 is a bench top high voltage probe which connects to the 4700 probe input to extend the measurement range up to 70KV. It is supplied with an ISO 17025 accredited certificate of calibration with data and uncertainties and a detachable toroid corona shield. Overall height is 370mm with 1.8m cable.
HVL-70G Lab 70KV High Impedance Probe. The HVL-70G is a high impedance bench top high voltage probe which connects to the 4700 probe input to extend the measurement range up to 70 KV. Its higher impedance allows it to be used in electrostatic voltmeter applications. It is supplied with an ISO 17025 accredited certificate of calibration with data and uncertainties and a detachable toroid corona shield. Overall height is 370mm with 1.8m cable.
HVL-100 Lab Precision 100KV High Voltage Probe. The HVL-100 is a bench top high voltage probe which connects to the 4700 probe input to extend the measurement range up to 100KV. It is supplied with an ISO 17025 accredited certificate of calibration with data and uncertainties and a detachable toroid corona shield. Overall height is 495mm with 1.8m cable.
HVL-100G Lab High Impedance 100KV High Voltage Probe. The HVL-100G is a high impedance bench top high voltage probe which connects to the 4700 probe input to extend the measurement range up to 100 KV. Its higher impedance allows it to be used in electrostatic voltmeter applications. It is supplied with an ISO 17025 accredited certificate of calibration with data and uncertainties and a detachable toroid corona shield. Overall height is 495mm with 1.8m cable.
HVL-150 Lab Precision 150KV High Voltage Probe. The HVL-150 is a bench top high voltage probe which connects to the 4700 probe input to extend the measurement range up to 140KV. It is supplied with an ISO 17025 accredited certificate of calibration (up to 90KV) with data and uncertainties and a detachable toroid corona shield. Overall height is 735mm with 1.8m cable.
TL-47 Replacement Direct Input Test Lead Set. This replacement test lead kit includes a 20KV rated direct input HV lest lead, a common input lead (both 4 ft length, terminated in alligator clips) and a 6 ft length chassis grounding lead.
PB-47 Power Brick. Replacement External Power Source for the 4700 and 964i.
USB-1 USB A to B Cable 6ft (95X/4700 to printer or V7X/PA900 to PC)
USB-2 USB A to RS232 (Serial) Adapter Cable (Requires RS-2)
RS-2 Female to Female Null Modem RS232 (Serial) Cable 6ft
GP-1 1 Meter Shielded GPIB (IEE-488) Cable

 
Ladbrokes Review L.BetRoll