Fluke 718 Pressure Calibrator

Features

The Fluke 718 Pressure Calibrator provides a total pressure calibration solution for transmitters, gauges and switches. This compact pressure calibration solution is about a third of the size of comparable instruments and weighs just one kilogram (two pounds). The unique easy to clean pump helps protect the pump from damage and provides the ability to service the pump without disassembly, even in the field.

 

Specs

Technical Specifications

Fluke 718 Series

Measure pressure (Internal sensor)
Accuracy 0.025% full scale
Functions Zero, min/max, hold, damp

Dry air, non-corrosives only

Fluke 718 1G

Range -1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa)
Resolution 0.0001 psi, 0.001 mbar, 0.0001 kPa
Over pressure 5x Full Scale
Functions Zero, Min, Max, Hold, Damp

Fluke 718 30G

Range -12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)
Resolution 0.001 psi, 0.1 mbar, 0.01 kPa
Over pressure 5x Full Scale
Functions Zero, Min, Max, Hold, Damp

Fluke 718 100G

Range -12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)
Resolution 0.01 psi, 0.1 mbar, 0.01 kPa
Over pressure 2x Full Scale
Functions Zero, Min, Max, Hold, Damp

Fluke 718 300G

Range -12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa)
Resolution 0.01 psi, 1 mbar, 0.1 kPa
Over pressure 375 psi 25 bar
Functions Zero, Min, Max, Hold, Damp

Fluke 718 series via 700 Series Pressure Modules

Range 29 pressure modules, 0 – 1 inH20 to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs
Resolution Per pressure module specs
Accuracy To 0.025% of full span, per pressure module specs
Functions Zero, Min, Max, Hold, Damp

Media compatibility per pressure module specs

Fluke 718 Series Via Built in Pump

Range -12 psi or -850 mbar to full scale Supported Pressure Units; psi, inH20 (4°C), inH20 (20°C), cmH20 (4°C), cmH20 (20°C), bar, mbar, kPa, inHg, mmHg, kg/cm
Loop power range 24 V DC
Accuracy ±10%

Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V

mA Measure

Range 0 mA to 24 mA
Resolution 0.001 mA
Accuracy 0.015% + 1 count

General Specifications

Maximum voltage 30 volts (non-operating)
Temperature -40°C to 60°C
Operating temperature -10°C to 55°C
Relative humidity 95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C)
Operating altitude 3,000 M max
Shock 1 M drop test
Vibration Random, 2 g, 5 Hz – 500 Hz
Safety CSA C22.2 No. 1010.1: 1992
EMC EN50082-1: 1992 and EN55022: 1994 Class B
Size 216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in)
Weight 992 g (35 oz)
Power, battery life 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718
Battery life 4 to 20 hours typical, depending on functions used
Display LCD, 5 digit pressure and current simultaneous

For use with non-corrosive gasses

 

Models

Model Name Consist of Price
FLUKE 718 1G
  • Fluke 718 1G Pressure Calibrator
    -1 to 1 psi, (-68.9 mbar to 68.9 mbar, -6.89 to 6.89 kPa)
  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
FLUKE 718 30G
  • Fluke 718 30G Pressure Calibrator
    -12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)
  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
FLUKE 718 100G
  • Fluke 718 100G Pressure Calibrator
    -12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)
  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
FLUKE 718 300G
  • Fluke 718 300G Pressure Calibrator
    -12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa )
  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data

 