Fluke T6-1000 Electrical Tester

Features


Measure voltage … without test leads

FieldSense technology lets you slide the open fork over a conductor and see the voltage level.1

  •     Be safer: Measure voltage to 1000 V ac through the open fork, without test leads.
  •     Be faster: No need to open covers or remove wire nuts.
  •     Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).


Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage.+ Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier.


1 Requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.

Specs

 

Measurement Specifications
Function Requires test leads Range Resolution Accuracy[1]
FieldSense
ac voltage
No 1000 V 1 V ± (3 % + 3 counts) 45 Hz - 66 Hz[2][3]
FieldSense
ac current
No 200.0 A 0.1 A ± (3% + 3 counts) 45 Hz - 66 Hz
FieldSense
frequency (Hz)
No 45 Hz – 66 Hz 1 Hz ± (1% + 2 counts)[3]
Volts ac Yes 1000 V 1 V ± (1.5% + 2 counts) 45 Hz - 66 Hz
Volts dc Yes 1000 V 1 V ± (1% + 2 counts)
Resistance Yes 2000 Ω 1 Ω ± (1% + 2 counts)
Yes 20.00 kΩ 0.01 kΩ
Yes 100.0 kΩ 0.1 kΩ
Safety   1000 V CAT III
600 V CAT IV
   
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

 

General Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 x 259.3 x 43.8 mm
Jaw opening 17.8 mm
Weight 0.35 kg (0.78 lb)
Temperature
Operating:
Storage:
  -10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating:
Storage:
  2,000 m (6,562 feet)
10,000 m (32,808 feet)
Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)
Safety IEC/EN 61010-1: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable